Thursday, March 28, 2013

Omreport doesn't update disk rebuild progress

Had to replace a hard drive on a Dell Server and omreport rebuild progress got stuck at 1%.

The solution is to restart the srvadmin service :

 # srvadmin-services.sh restart  

This is quite dirty but it's the only solution I found. This also happened when I changed a PERC H700 battery.

Another way to check the rebuild process is to export log with omconfig :

 # omconfig storage controller action=exportlog controller=0  

This creates a /var/log/lsi_MMDD.log file, with the rebuild progress :

 03/09/13 22:07:51: EVT#13296-03/09/13 22:07:51: 99=Rebuild complete on VD 01/1  
 03/09/13 22:07:51: EVT#13297-03/09/13 22:07:51: 100=Rebuild complete on PD 05(e0x20/s5)  
 03/09/13 22:07:51: EVT#13298-03/09/13 22:07:51: 114=State change on PD 05(e0x20/s5) from REBUILD(14) to ONLINE(18)  
 03/09/13 22:07:51: EVT#13299-03/09/13 22:07:51: 81=State change on VD 01/1 from DEGRADED(2) to OPTIMAL(3)  
 03/09/13 22:07:51: EVT#13300-03/09/13 22:07:51: 249=VD 01/1 is now OPTIMAL  

Same thing for the battery learn cycle.

Hope that helps !